Method & assumptions

  1. Convert positive intensity to level: L = 10 log₁₀(I/Iref).
  2. Default reference: 10⁻¹² W/m². Example: I = 10⁻⁶ W/m² gives 60 dB.
  3. Negative levels are valid below the reference. Zero intensity corresponds to negative infinity and is excluded.
  4. This is intensity level, not sound-pressure level, A-weighted level or perceived loudness.